Vol. 12 No. 2 : 2017 - DAYANG ANITA AA et al.

Central Venous Line (CVL) catheter can easily dislodge. An improvised technique in three easily reproducible steps is described in detail. The placement of the cuff approximately 1cm from the exit wound with the placement of additional sutures at the neck area helps prevent its displacement.

Vol. 13 No. 1 : 2018 - HUSAIN S et al.

Epistaxis is one of the common presenting symptoms of patients with hereditary haemorrhagic telangiectasia (HHT). Majority of patients required blood transfusion due to intractable nasal bleeding. Septodermoplasty is an effective treatment for HHT, however it gives rise to persistent nasal crusting and foul smelling nasal discharge post surgery. We present an endoscopic septomucoplasty using buccal mucosa graft as an alternative technique to septodermoplasty.