Share |

External Marker in Bisecting-Angle-Technique: A New Approach to Minimize Dental Radiographic Error

Original article

Abstrak

Teknik ‘bisecting-angle’ merupakan satu kaedah yang digunakan bagi menambah baik keselesaan pesakit semasa radiografi periapikal. Kebiasaannya, teknik ini dilakukan tanpa menggunakan alat sasaran sinar-X dan sering kali mengakibatkan ralat pada radiograf pergigian. Penggunaan penanda luaran sebagai alat bantuan bagi mensasarkan sinar-X di dalam teknik ‘bisecting-angle’ adalah berpotensi bagi mengurangkan ralat radiograf berkenaan. Dalam kajian ini, 240 radiograf periapikal diambil oleh pelajar sarjana muda pergigian dengan menggunakan 3 jenis teknik radiograf periapikal. Teknik-teknik ini adalah teknik ‘bisecting-angle’ (BAT), teknik ‘bisecting-angle’ dengan menggunakan penanda luaran (BAT-M) dan teknik ‘paralleling’ (PT). Setiap radiograf yang diambil, seterusnya dinilai dan ralat yang terdapat pada radiograf diklasifikasikan dan dijadualkan mengikut jenis dan bilangan ralat radiograf yang berlaku. Analisis statistik yang lebih terperinci turut dilakukan bagi membandingkan jumlah bilangan ralat radiograf yang melibatkan ketiga-tiga teknik berkenaan. Keputusan kajian menunjukkan salah satu ralat radiograf yang sering terjadi dengan BAT adalah ralat potongan kon (13.8%). Ralat ini didapati berkurangan kepada 1.3% dan 2.5% dengan pelaksanaan BAT-M dan PT, masing-masing. Jumlah keseluruhan ralat radiograf juga didapati jauh lebih kecil dengan BAT- M berbanding BAT, p <0.05.

Kata kunci

Abstract

Bisecting-angle-technique is a method  used  to improve  patient  comfort  during
periapical radiography. This technique is usually  performed without  X-ray beam aiming device and has been commonly associated with dental radiographic error.
The use of external marker as a beam  aiming device  in bisecting-angle-technique
is potentially  effective to reduce  the number  of errors occurring  during periapical radiography. In this study, 240 periapical radiographs were taken by undergraduate dental  students.  Periapical  radiographs were  taken  using  traditional  method  of bisecting-angle-technique (BAT), bisecting-angle-technique with the use of external marker  (BAT-M) and  the  standard  method  in periapical radiography; paralleling technique (PT). All radiographic images were evaluated and errors were classified and tabled according to the type and number of errors. Chi-square test was used to compare the total number of radiographic errors made using these three techniques. One  of the most common errors with BAT was cone  cut error (13.8%). This error had been  markedly  reduced to 1.3% and 2.5% by implementation of BAT-M and PT, respectively.  The total number of errors was also found to be significantly lesser for BAT-M compared to BAT, p< 0.05.